Rotating & cooling

Units

Capacities shown in metric units.Capacities shown in imperial units. The published JSON is in each equipment record's native units and in USD, and does not change with this control. Unit conversion is exact and reversible; the exponents are dimensionless and identical in both systems.

EquipmentReference size s_refReference cost c_ref, USDEquipment exponent n_eqpInstalled exponent n_instMultiple at s_ref icm_refValid rangeEvidence
Cooling tower, induced draftm³/hgpm15°F range / 10°F approachThe most extreme installed-cost gradient in the register: ICM runs from about 15× at 150 gpm to about 2× at 6000 gpm. A constant multiple here would be catastrophically wrong at the small end. 1000 gpm ≈ 2.2 MW_cooling at 15°F range.227.1 m³/h1,000 gpm$19,7930.86810.32725.06134.07–1,362.74 m³/h150–6,000 gpmEstimated
Reciprocating air compressor, 1 stagem³/hacfm60 psia dischargeNote the published disagreement: textbook exponents for reciprocating compressors span 0.18 to 0.72 across three standard sources. This regressed value of 0.576 sits mid-range and is derived, not cited.6,796 m³/h4,000 acfm$739,8230.57570.54511.213424.76–101,940.64 m³/h250–60,000 acfmEstimated
Centrifugal compressor, 4 stagem³/hacfm50 psia dischargeWidest validated capacity range in the register at 400×, which exceeds the tenfold rule — the calculator should warn beyond one decade either side of S_ref even though the fit range is wider.16,990 m³/h10,000 acfm$1,846,3330.46260.45731.175849.51–339,802.15 m³/h500–200,000 acfmEstimated
Centrifugal pump, carbon steelm³/hgpmcarbon steelNarrow validated range (10×) and only three points on the equipment fit. Treat the exponent as provisional.681.4 m³/h3,000 gpm$18,8540.74430.38123.844227.13–2,271.24 m³/h1,000–10,000 gpmEstimated
Industrial chillerMW_coolingtonheat removed, NOT electrical inputNot published — regression pending — No capital-cost scaling exponent for chillers was found in any accessible public source. The input is the DOE appliance and equipment standards Technical Support Documents, which tabulate manufacturer selling price and installed cost by capacity bin and are public domain. Leave disabled in the UI until regressed.Not published
Motor and variable-speed drivekWhpnameplate shaft powerNot published — regression pending — Pending. Note the register shows explosion-proof motor exponents disagreeing across sources (0.39 / 0.61 / 0.66), so a derived value is worth having.Not published

How to cite

Pemspring Energy Solutions, PEICI Rotating & cooling factor set 2026.1, published 2026-11-01. https://pemspring.com/cost-index/rotating-cooling/

Published values are in USD and in native units — gpm, acfm, MW_cooling, kW — regardless of the unit control above. Cite the native value: it is what the JSON contains and what a later version will be compared against.