    "set_id": "rotating-cooling",
    "set_name": "Rotating & cooling",
    "version": "2026.1",
    "status": "seed",
    "published": "2026-11-01",
    "base_currency": "USD",
    "base_region": "NA",
    "accuracy": {
        "class": "AACE Class 5",
        "definition": "0–2% project definition, concept screening",
        "low_pct": [
            -20,
            -50
        ],
        "high_pct": [
            30,
            100
        ],
        "source": "AACE International Recommended Practice 18R-97"
    },
    "location_factors": {
        "_comment": "Location factors are ESTIMATED and INPUT-PRICE ONLY - they exclude delivery-environment cost. Published with a range and a coverage grade in data/location-factors-2026.1.json; the range must be shown wherever the point value is. Base region NA = 1.000 by definition (US Gulf Coast). See 16-location-factors.md.",
        "NA": 1,
        "EU": 0.957,
        "APAC": 0.931,
        "SAM": 0.931,
        "MEA": 0.887
    },
    "sources": [
        {
            "id": "netl-1169",
            "title": "Process Equipment Cost Estimation, Final Report",
            "publisher": "US DOE / NETL",
            "ref": "DOE/NETL-2002/1169",
            "url": "https://www.osti.gov/servlets/purl/797810/",
            "licence": "US federal — public domain",
            "cost_year": 1998
        }
    ],
    "equipment": [
        {
            "id": "coolingTower",
            "name": "Cooling tower, induced draft",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "gpm",
                "label": "gpm circulating water",
                "basis": "15°F range / 10°F approach",
                "mw_conversion": {
                    "to": "MW_cooling",
                    "expression": "MW_cooling = gpm * 500 * range_f / 3412142",
                    "defaults": {
                        "range_f": 15
                    },
                    "evidence": "assumed",
                    "note": "Standard heat-balance conversion at the stated range. Changing the range changes the duty proportionally."
                }
            },
            "s_ref": 1000,
            "c_ref": 19793,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.8681,
            "n_inst": 0.3272,
            "icm_ref": 5.061,
            "valid_min": 150,
            "valid_max": 6000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.998,
                "r2_inst": 0.908,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "The most extreme installed-cost gradient in the register: ICM runs from about 15× at 150 gpm to about 2× at 6000 gpm. A constant multiple here would be catastrophically wrong at the small end. 1000 gpm ≈ 2.2 MW_cooling at 15°F range."
        },
        {
            "id": "recipCompressor",
            "name": "Reciprocating air compressor, 1 stage",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "acfm",
                "label": "actual cfm",
                "basis": "60 psia discharge",
                "mw_conversion": {
                    "to": "kW_shaft",
                    "expression": "kW_shaft = acfm / acfm_per_kw",
                    "defaults": {
                        "acfm_per_kw": 6
                    },
                    "evidence": "assumed",
                    "note": "Rule-of-thumb specific power at moderate discharge pressure. HIGHLY pressure-dependent — flag prominently and let the user override. Do not present as measured."
                }
            },
            "s_ref": 4000,
            "c_ref": 739823,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.5757,
            "n_inst": 0.5451,
            "icm_ref": 1.213,
            "valid_min": 250,
            "valid_max": 60000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.944,
                "r2_inst": 0.941,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "Note the published disagreement: textbook exponents for reciprocating compressors span 0.18 to 0.72 across three standard sources. This regressed value of 0.576 sits mid-range and is derived, not cited."
        },
        {
            "id": "centrifugalCompressor",
            "name": "Centrifugal compressor, 4 stage",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "acfm",
                "label": "actual cfm",
                "basis": "50 psia discharge",
                "mw_conversion": {
                    "to": "kW_shaft",
                    "expression": "kW_shaft = acfm / acfm_per_kw",
                    "defaults": {
                        "acfm_per_kw": 6
                    },
                    "evidence": "assumed",
                    "note": "As above — pressure-dependent rule of thumb, not a measurement."
                }
            },
            "s_ref": 10000,
            "c_ref": 1846333,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.4626,
            "n_inst": 0.4573,
            "icm_ref": 1.175,
            "valid_min": 500,
            "valid_max": 200000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.923,
                "r2_inst": 0.928,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "Widest validated capacity range in the register at 400×, which exceeds the tenfold rule — the calculator should warn beyond one decade either side of S_ref even though the fit range is wider."
        },
        {
            "id": "centrifugalPump",
            "name": "Centrifugal pump, carbon steel",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "gpm",
                "label": "gpm",
                "basis": "carbon steel",
                "note": "No MW conversion offered. Shaft power depends on head, specific gravity and efficiency — four unknowns the calculator cannot assume. Native units only.",
                "mw_conversion": null
            },
            "s_ref": 3000,
            "c_ref": 18854,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.7443,
            "n_inst": 0.3812,
            "icm_ref": 3.844,
            "valid_min": 1000,
            "valid_max": 10000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.978,
                "r2_inst": 0.924,
                "n_points": 3,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "Narrow validated range (10×) and only three points on the equipment fit. Treat the exponent as provisional."
        },
        {
            "id": "chiller",
            "name": "Industrial chiller",
            "status": "pending_regression",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "MW_cooling",
                "label": "MW cooling (heat removed)",
                "basis": "heat removed, NOT electrical input",
                "mw_conversion": {
                    "to": "MW_cooling",
                    "expression": "MW_cooling = tons * 0.003516853",
                    "defaults": {},
                    "evidence": "measured",
                    "note": "1 ton of refrigeration = 12,000 Btu/h = 3.516853 kW exactly. This converts the COOLING duty. Electrical input is smaller by the COP (typically 4–7) — the two must never be confused."
                }
            },
            "s_ref": null,
            "c_ref": null,
            "c_ref_cost_year": null,
            "n_eqp": null,
            "n_inst": null,
            "icm_ref": null,
            "valid_min": null,
            "valid_max": null,
            "max_single_unit": null,
            "evidence": null,
            "fit": null,
            "needs_regression": true,
            "sources": [],
            "notes": "No capital-cost scaling exponent for chillers was found in any accessible public source. The input is the DOE appliance and equipment standards Technical Support Documents, which tabulate manufacturer selling price and installed cost by capacity bin and are public domain. Leave disabled in the UI until regressed."
        },
        {
            "id": "motorVsd",
            "name": "Motor and variable-speed drive",
            "status": "pending_regression",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "kW",
                "label": "kW shaft",
                "basis": "nameplate shaft power"
            },
            "s_ref": null,
            "c_ref": null,
            "c_ref_cost_year": null,
            "n_eqp": null,
            "n_inst": null,
            "icm_ref": null,
            "valid_min": null,
            "valid_max": null,
            "max_single_unit": null,
            "evidence": null,
            "fit": null,
            "needs_regression": true,
            "sources": [],
            "notes": "Pending. Note the register shows explosion-proof motor exponents disagreeing across sources (0.39 / 0.61 / 0.66), so a derived value is worth having."
        }
    ]
}