Every cost–capacity scaling exponent Pemspring has fitted, including the ones that did not meet the quality bar. This is the working data behind the Cost Index: free to read, free to cite, and published in full rather than in summary.
A scaling exponent describes how cost moves with capacity. An exponent of 1.0 means cost rises in step with size; below 1.0 means larger plant costs proportionally less, which is the economy of scale the six-tenths rule approximates. These are fitted to published cost data by ordinary least squares on log-transformed cost and capacity.
88 fits · 77 meet the quality bar · 14 exponents promoted into 7 published records
Across the 39 qualifying fits on an equipment-cost basis, the median fitted exponent is 0.61, ranging from 0.30 to 1.42. 18 of 39 fall below the six-tenths default.
On an installed-cost basis — 38 qualifying fits — the median is 0.49, ranging from 0.23 to 1.27. That gap is the register's second finding: installed cost scales more gently than equipment cost, which is what makes the installed-cost multiple fall as capacity rises — in 36 of 37 equipment types.
The two bases are quoted separately on purpose. A median taken across both mixes things that scale differently and is not comparable with the six-tenths convention, which is an equipment-cost rule.
Showing all 88 fits
Download the register as CSV — free, no subscription, quality-bar rule in the file header.
| Equipment | Subtype | Capacity unit | Basis | Exponent n | R² | Points | Range | Quality bar | Source |
|---|---|---|---|---|---|---|---|---|---|
| Agitator# | 1800 RPM | hp | installed | 0.4781 | 0.9348 | 3 | 50× | Meets | NETL AppB p67high confidence |
| Agitator# | 1800 RPM | hp | purchased | 0.5212 | 0.9443 | 3 | 50× | Meets | NETL AppB p67high confidence |
| Air Compressor# | R3_FS_L_XX baseline EL0 | acfm | purchased | 0.751 | 1 | 3 | 4× | Failscapacity range 4×, below the 10× minimum | DOE Compressors ECS NOPR Table IV.25high confidence |
| Air Compressor# | RP_FS_LF_AC baseline EL0 | acfm | purchased | 0.5702 | 0.9619 | 3 | 50× | Meets | DOE Compressors ECS NOPR Table IV.23high confidence |
| Air Compressor# | RP_FS_L_AC baseline EL0 | acfm | purchased | 0.9522 | 0.9994 | 3 | 50× | Meets | DOE Compressors ECS NOPR Table IV.21high confidence |
| Air Compressor# | RP_VS_LF_AC baseline EL0 | acfm | purchased | 0.4266 | 0.8801 | 4 | 500× | FailsR² 0.8801, below the 0.90 minimum | DOE Compressors ECS NOPR Table IV.24high confidence |
| Air Compressor# | RP_VS_L_AC baseline EL0 | acfm | purchased | 0.9509 | 1 | 3 | 50× | Meets | DOE Compressors ECS NOPR Table IV.22high confidence |
| Air Cooler# | CS tubes, Al fins | ft2 bare tube | installed | 0.3709 | 0.91 | 4 | 100× | Meets | NETL AppB p59high confidence |
| Air Cooler# | CS tubes, Al fins | ft2 bare tube | purchased | 0.4884 | 0.9418 | 4 | 100× | Meets | NETL AppB p59high confidence |
| Centrifugal Compressor# | 4 stage, 50 psia discharge | acfm | installed | 0.4573 | 0.9281 | 4 | 400× | Meetspromoted to centrifugalCompressor | NETL AppB p71high confidence |
| Centrifugal Compressor# | 4 stage, 50 psia discharge | acfm | purchased | 0.4626 | 0.9233 | 4 | 400× | Meetspromoted to centrifugalCompressor | NETL AppB p71high confidence |
| Centrifugal Compressor# | 7-9 stage, 150 psia discharge | acfm | installed | 0.4944 | 0.9068 | 3 | 400× | Meets | NETL AppB p71high confidence |
| Centrifugal Compressor# | 7-9 stage, 150 psia discharge | acfm | purchased | 0.499 | 0.906 | 3 | 400× | Meets | NETL AppB p71high confidence |
| Centrifugal Compressor# | 9 stage, 1900 psia discharge | acfm | installed | 0.3579 | 0.8856 | 3 | 30× | FailsR² 0.8856, below the 0.90 minimum | NETL AppB p71high confidence |
| Centrifugal Compressor# | 9 stage, 1900 psia discharge | acfm | purchased | 0.3468 | 0.867 | 3 | 30× | FailsR² 0.8670, below the 0.90 minimum | NETL AppB p71high confidence |
| Centrifugal Fan# | CS, 1800 RPM, 6 in H2O | gpm (as printed; see note F2) | installed | 0.535 | 0.9143 | 4 | 214.3× | Meets | NETL AppB p71medium confidence |
| Centrifugal Fan# | CS, 1800 RPM, 6 in H2O | gpm (as printed; see note F2) | purchased | 0.6824 | 0.9163 | 4 | 214.3× | Meets | NETL AppB p71medium confidence |
| Centrifugal Pump# | CS | gpm | installed | 0.3812 | 0.9243 | 4 | 100× | Meetspromoted to centrifugalPump | NETL AppB p68high confidence |
| Centrifugal Pump# | CS | gpm | purchased | 0.7443 | 0.9783 | 3 | 10× | Meetspromoted to centrifugalPump | NETL AppB p68high confidence |
| Centrifuge# | Batch top-suspended filtering | in screen dia | installed | 0.8824 | 0.9974 | 3 | 2.5× | Failscapacity range 2.5×, below the 10× minimum | NETL AppB p65high confidence |
| Centrifuge# | Batch top-suspended filtering | in screen dia | purchased | 1.2892 | 1 | 3 | 2.5× | Failscapacity range 2.5×, below the 10× minimum | NETL AppB p65high confidence |
| Cooling Tower# | 15F range/10F approach | gpm | installed | 0.3272 | 0.9085 | 4 | 40× | Meetspromoted to coolingTower | NETL AppB p60high confidence |
| Cooling Tower# | 15F range/10F approach | gpm | purchased | 0.8681 | 0.9975 | 4 | 40× | Meetspromoted to coolingTower | NETL AppB p60high confidence |
| Crusher# | Gyratory | hp | installed | 1.2693 | 0.9998 | 3 | 31.2× | Meets | NETL AppB p62high confidence |
| Crusher# | Gyratory | hp | purchased | 1.4172 | 0.9994 | 3 | 31.2× | Meets | NETL AppB p62high confidence |
| Crusher# | Ring granulator | hp | installed | 0.9407 | 0.9975 | 3 | 16.7× | Meets | NETL AppB p62high confidence |
| Crusher# | Ring granulator | hp | purchased | 0.9727 | 0.997 | 3 | 16.7× | Meets | NETL AppB p62high confidence |
| Crusher# | Rotary | hp | installed | 0.4917 | 0.9943 | 3 | 12.5× | Meets | NETL AppB p62high confidence |
| Crusher# | Rotary | hp | purchased | 0.7036 | 1 | 3 | 12.5× | Meets | NETL AppB p62high confidence |
| Dryer# | Atmospheric tray batch | ft2 | installed | 0.3529 | 0.9999 | 3 | 6.7× | Failscapacity range 6.7×, below the 10× minimum | NETL AppB p64high confidence |
| Dryer# | Atmospheric tray batch | ft2 | purchased | 0.3857 | 1 | 3 | 6.7× | Failscapacity range 6.7×, below the 10× minimum | NETL AppB p64high confidence |
| Dryer# | Direct contact rotary | ft2 | installed | 0.8855 | 1 | 3 | 20× | Meets | NETL AppB p64high confidence |
| Dryer# | Direct contact rotary | ft2 | purchased | 0.9539 | 1 | 3 | 20× | Meets | NETL AppB p64high confidence |
| Dryer# | Single atmospheric drum | ft2 | installed | 0.5777 | 1 | 3 | 20× | Meets | NETL AppB p64high confidence |
| Dryer# | Single atmospheric drum | ft2 | purchased | 0.6119 | 1 | 3 | 20× | Meets | NETL AppB p64high confidence |
| Evaporator# | Standard horizontal tube | ft2 | installed | 0.4928 | 1 | 3 | 100× | Meets | NETL AppB p61high confidence |
| Evaporator# | Standard horizontal tube | ft2 | purchased | 0.5303 | 1 | 3 | 100× | Meets | NETL AppB p61high confidence |
| Evaporator# | Standard vertical tube | ft2 | installed | 0.5151 | 0.9999 | 3 | 60× | Meets | NETL AppB p61high confidence |
| Evaporator# | Standard vertical tube | ft2 | purchased | 0.5494 | 1 | 3 | 60× | Meets | NETL AppB p61high confidence |
| Filter# | Cartridge | cfm (see note F1) | installed | 0.2819 | 0.9539 | 3 | 40× | Meets | NETL AppB p66medium confidence |
| Filter# | Cartridge | cfm (see note F1) | purchased | 0.4954 | 0.9419 | 3 | 40× | Meets | NETL AppB p66medium confidence |
| Filter# | Drum | ft2 | installed | 0.351 | 0.9975 | 3 | 20× | Meets | NETL AppB p66high confidence |
| Filter# | Drum | ft2 | purchased | 0.3971 | 1 | 3 | 20× | Meets | NETL AppB p66high confidence |
| Filter# | Tubular fabric | cfm (see note F1) | installed | 0.5168 | 0.9977 | 3 | 34× | Meets | NETL AppB p66medium confidence |
| Filter# | Tubular fabric | cfm (see note F1) | purchased | 0.6524 | 1 | 3 | 34× | Meets | NETL AppB p66medium confidence |
| Furnace / Process Heater# | CS tubes, 500 psig | MMBtu/hr | installed | 0.6979 | 0.9836 | 4 | 50× | Meetspromoted to processHeater | NETL AppB p60high confidence |
| Furnace / Process Heater# | CS tubes, 500 psig | MMBtu/hr | purchased | 0.6906 | 0.991 | 4 | 50× | Meetspromoted to processHeater | NETL AppB p60high confidence |
| Gas Turbine# | CS | hp | installed | 0.7605 | 0.9911 | 6 | 370× | Meets | NETL AppB p72high confidence |
| Gas Turbine# | CS | hp | purchased | 0.7833 | 0.9927 | 6 | 370× | Meets | NETL AppB p72high confidence |
| Horizontal Vessel# | 15 psig, A515 CS | gallons | installed | 0.2844 | 0.9802 | 4 | 1,000× | Meets | NETL AppB p53high confidence |
| Horizontal Vessel# | 15 psig, A515 CS | gallons | purchased | 0.4083 | 0.9864 | 4 | 1,000× | Meets | NETL AppB p53high confidence |
| Horizontal Vessel# | 150 psig, A515 CS | gallons | installed | 0.3612 | 0.9482 | 4 | 1,000× | Meets | NETL AppB p53high confidence |
| Horizontal Vessel# | 150 psig, A515 CS | gallons | purchased | 0.5567 | 0.9713 | 4 | 1,000× | Meets | NETL AppB p53high confidence |
| Mill# | Ball mill | hp | installed | 0.5712 | 0.9922 | 3 | 60× | Meets | NETL AppB p63high confidence |
| Mill# | Ball mill | hp | purchased | 0.7689 | 1 | 3 | 60× | Meets | NETL AppB p63high confidence |
| Mill# | Roller mill | hp | installed | 0.586 | 1 | 3 | 13.3× | Meets | NETL AppB p63high confidence |
| Mill# | Roller mill | hp | purchased | 0.6113 | 1 | 3 | 13.3× | Meets | NETL AppB p63high confidence |
| Package Steam Boiler# | A285C, 250 psig | lb/hr | installed | 0.4248 | 0.9747 | 4 | 30× | Meetspromoted to packageSteamBoiler | NETL AppB p61high confidence |
| Package Steam Boiler# | A285C, 250 psig | lb/hr | purchased | 0.6318 | 0.9876 | 4 | 30× | Meetspromoted to packageSteamBoiler | NETL AppB p61high confidence |
| Reciprocating Compressor# | 1 stage, 60 psia discharge | acfm | installed | 0.5451 | 0.941 | 4 | 240× | Meetspromoted to recipCompressor | NETL AppB p70high confidence |
| Reciprocating Compressor# | 1 stage, 60 psia discharge | acfm | purchased | 0.5757 | 0.9439 | 4 | 240× | Meetspromoted to recipCompressor | NETL AppB p70high confidence |
| Reciprocating Compressor# | 3 stage, 440 psia discharge | acfm | installed | 0.5354 | 0.9473 | 3 | 140× | Meets | NETL AppB p70high confidence |
| Reciprocating Compressor# | 3 stage, 440 psia discharge | acfm | purchased | 0.5564 | 0.9534 | 3 | 140× | Meets | NETL AppB p70high confidence |
| Reciprocating Pump# | Duplex, CS | gpm | installed | 0.4082 | 0.9941 | 3 | 40× | Meets | NETL AppB p69high confidence |
| Reciprocating Pump# | Duplex, CS | gpm | purchased | 0.5674 | 0.9999 | 3 | 40× | Meets | NETL AppB p69high confidence |
| Reciprocating Pump# | Triplex, CS | gpm | installed | 0.4876 | 0.9954 | 3 | 40× | Meets | NETL AppB p69high confidence |
| Reciprocating Pump# | Triplex, CS | gpm | purchased | 0.6279 | 0.9999 | 3 | 40× | Meets | NETL AppB p69high confidence |
| Rotary Blower# | CS, 1800 RPM, 8 psig | gpm (as printed; see note F2) | installed | 0.4135 | 0.9785 | 3 | 40× | Meets | NETL AppB p72medium confidence |
| Rotary Blower# | CS, 1800 RPM, 8 psig | gpm (as printed; see note F2) | purchased | 0.5457 | 0.9947 | 3 | 40× | Meets | NETL AppB p72medium confidence |
| Rotary Pump# | Cast iron | gpm | installed | 0.2295 | 0.904 | 4 | 75× | Meets | NETL AppB p67-68high confidence |
| Rotary Pump# | Cast iron | gpm | purchased | 0.7473 | 0.9563 | 3 | 7.5× | Failscapacity range 7.5×, below the 10× minimum | NETL AppB p67-68high confidence |
| Shell and Tube Heat Exchanger# | CS, 150 psig | ft2 | installed | 0.5039 | 0.8926 | 6 | 700× | FailsR² 0.8926, below the 0.90 minimum | NETL AppB p58high confidence |
| Shell and Tube Heat Exchanger# | CS, 150 psig | ft2 | purchased | 0.6467 | 0.9229 | 6 | 700× | Meets | NETL AppB p58high confidence |
| Spiral Plate Heat Exchanger# | SS304, 150 psig | ft2 | installed | 0.5217 | 0.9757 | 4 | 32.5× | Meets | NETL AppB p59high confidence |
| Spiral Plate Heat Exchanger# | SS304, 150 psig | ft2 | purchased | 0.6538 | 0.9711 | 4 | 32.5× | Meets | NETL AppB p59high confidence |
| Steam Turbine# | over 1000 hp | hp | installed | 0.7849 | 0.9966 | 4 | 30× | Meets | NETL AppB p73high confidence |
| Steam Turbine# | over 1000 hp | hp | purchased | 0.7565 | 1 | 3 | 6× | Failscapacity range 6×, below the 10× minimum | NETL AppB p73high confidence |
| Steam Turbine# | under 1000 hp | hp | installed | 0.2759 | 0.9543 | 3 | 95× | Meets | NETL AppB p73high confidence |
| Storage Tank# | Cone roof, CS | gallons | installed | 0.6288 | 0.9655 | 4 | 200× | Meetspromoted to thermalStorageTank | NETL AppB p54high confidence |
| Storage Tank# | Cone roof, CS | gallons | purchased | 0.7381 | 0.986 | 4 | 200× | Meetspromoted to thermalStorageTank | NETL AppB p54high confidence |
| Storage Tank# | Floating roof, CS | gallons | installed | 0.5267 | 0.9546 | 4 | 200× | Meets | NETL AppB p54high confidence |
| Storage Tank# | Floating roof, CS | gallons | purchased | 0.5644 | 0.964 | 4 | 200× | Meets | NETL AppB p54high confidence |
| Vacuum Pump# | 1 stage, CS | gpm (as printed) | installed | 0.3023 | 0.959 | 3 | 23.3× | Meets | NETL AppB p69high confidence |
| Vacuum Pump# | 1 stage, CS | gpm (as printed) | purchased | 0.6536 | 0.9925 | 3 | 23.3× | Meets | NETL AppB p69high confidence |
| Vertical Vessel# | 15 psig, A515 CS | gallons | installed | 0.2615 | 0.9948 | 4 | 50× | Meets | NETL AppB p52high confidence |
| Vertical Vessel# | 15 psig, A515 CS | gallons | purchased | 0.3037 | 0.9999 | 4 | 50× | Meets | NETL AppB p52high confidence |
| Vertical Vessel# | 150 psig, A515 CS | gallons | installed | 0.2413 | 0.9992 | 4 | 50× | Meets | NETL AppB p52high confidence |
| Vertical Vessel# | 150 psig, A515 CS | gallons | purchased | 0.3726 | 0.9977 | 4 | 50× | Meets | NETL AppB p52high confidence |
How to cite
Pemspring Energy Solutions, PEICI scaling exponent register v0.1. https://pemspring.com/cost-index/exponent-register/
To cite one fit rather than the register, use its row anchor — the # beside each equipment name is a permanent link to that row. Fit ids are stable across releases, so a citation made today still resolves after the next version is published.
Exponents are dimensionless. Capacity units are the units the data was fitted in and are not converted; costs are USD at the stated cost year. Neither varies with any display setting.