    "set_id": "heat",
    "set_name": "Heat",
    "version": "2026.1",
    "status": "seed",
    "published": "2026-11-01",
    "base_currency": "USD",
    "base_region": "NA",
    "accuracy": {
        "class": "AACE Class 5",
        "definition": "0–2% project definition, concept screening",
        "low_pct": [
            -20,
            -50
        ],
        "high_pct": [
            30,
            100
        ],
        "source": "AACE International Recommended Practice 18R-97"
    },
    "location_factors": {
        "_comment": "Location factors are ESTIMATED and INPUT-PRICE ONLY - they exclude delivery-environment cost. Published with a range and a coverage grade in data/location-factors-2026.1.json; the range must be shown wherever the point value is. Base region NA = 1.000 by definition (US Gulf Coast). See 16-location-factors.md.",
        "NA": 1,
        "EU": 0.957,
        "APAC": 0.931,
        "SAM": 0.931,
        "MEA": 0.887
    },
    "sources": [
        {
            "id": "netl-1169",
            "title": "Process Equipment Cost Estimation, Final Report",
            "publisher": "US DOE / NETL",
            "ref": "DOE/NETL-2002/1169",
            "url": "https://www.osti.gov/servlets/purl/797810/",
            "licence": "US federal — public domain",
            "cost_year": 1998
        }
    ],
    "equipment": [
        {
            "id": "htHeatPump",
            "name": "High-temperature industrial heat pump",
            "status": "pending_regression",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "MWth",
                "label": "MW thermal delivered",
                "basis": "heat delivered at sink temperature, NOT electrical input"
            },
            "s_ref": 10,
            "c_ref": null,
            "c_ref_cost_year": null,
            "n_eqp": null,
            "n_inst": null,
            "icm_ref": null,
            "valid_min": null,
            "valid_max": null,
            "max_single_unit": null,
            "evidence": null,
            "fit": null,
            "sources": [],
            "notes": "DEA Technology Data catalogue treated as licensed on client instruction, 4 September 2026 - the legal block is CLOSED. What remains is a DATA block, which was always the real one. No capacity-cost points have been extracted and no regression exists, so there is nothing to publish. One gate before this can be enabled: the regression run and passing the quality bar of 14-exponent-register.md section 3. Register v0.2 task. Record the licence document reference against the dea-tech source row before the first published value. Do NOT substitute a proxy - "
        },
        {
            "id": "electricBoiler",
            "name": "Electric boiler",
            "status": "pending_regression",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "MWth",
                "label": "MW thermal delivered",
                "basis": "steam or hot water raised"
            },
            "s_ref": 10,
            "c_ref": null,
            "c_ref_cost_year": null,
            "n_eqp": null,
            "n_inst": null,
            "icm_ref": null,
            "valid_min": null,
            "valid_max": null,
            "max_single_unit": null,
            "evidence": null,
            "fit": null,
            "sources": [],
            "notes": "DEA Technology Data catalogue treated as licensed on client instruction, 4 September 2026 - the legal block is CLOSED. What remains is a DATA block, which was always the real one. No capacity-cost points have been extracted and no regression exists, so there is nothing to publish. One gate before this can be enabled: the regression run and passing the quality bar of 14-exponent-register.md section 3. Register v0.2 task. Record the licence document reference against the dea-tech source row before the first published value. Do NOT substitute a proxy - "
        },
        {
            "id": "packageSteamBoiler",
            "name": "Package steam boiler (fossil comparator)",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "lb/hr",
                "label": "lb/hr steam",
                "basis": "A285C, 250 psig",
                "mw_conversion": {
                    "to": "MWth",
                    "expression": "MWth = lb_per_hr * enthalpy_btu_per_lb / 3412142",
                    "defaults": {
                        "enthalpy_btu_per_lb": 1000
                    },
                    "evidence": "assumed",
                    "note": "Enthalpy rise from feedwater to saturated steam. 1000 Btu/lb is a working default; the user must be able to override it and the conversion must be shown on screen."
                }
            },
            "s_ref": 50000,
            "c_ref": 236276,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.6318,
            "n_inst": 0.4248,
            "icm_ref": 2.213,
            "valid_min": 10000,
            "valid_max": 300000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.988,
                "r2_inst": 0.975,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "Included as the comparator an electrification business case is measured against. 50,000 lb/hr ≈ 14.65 MWth at the default enthalpy."
        },
        {
            "id": "processHeater",
            "name": "Electric process heater / furnace",
            "status": "seeded",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "MMBtu/hr",
                "label": "MMBtu/hr duty",
                "basis": "CS tubes, 500 psig",
                "mw_conversion": {
                    "to": "MWth",
                    "expression": "MWth = mmbtu_per_hr * 0.293071",
                    "defaults": {},
                    "evidence": "measured",
                    "note": "Exact unit conversion, not an assumption."
                }
            },
            "s_ref": 70,
            "c_ref": 918925,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.6906,
            "n_inst": 0.6979,
            "icm_ref": 1.329,
            "valid_min": 10,
            "valid_max": 500,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.991,
                "r2_inst": 0.984,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "Fired heater geometry. One of only two entries in the whole register where n_inst EXCEEDS n_eqp — installation scales slightly faster than equipment here. 70 MMBtu/hr = 20.5 MWth."
        },
        {
            "id": "thermalStorageTank",
            "name": "Thermal storage tank (partial)",
            "status": "partial",
            "model": "power_law",
            "c_ref_basis": "equipment",
            "rating": {
                "unit": "gallons",
                "label": "US gallons",
                "basis": "cone roof, carbon steel",
                "mw_conversion": {
                    "to": "MWh_th",
                    "expression": "MWh_th = gallons * 8.34 * cp_btu_per_lb_f * delta_t_f / 3412142",
                    "defaults": {
                        "cp_btu_per_lb_f": 1,
                        "delta_t_f": 50
                    },
                    "evidence": "assumed",
                    "note": "Water, sensible heat only. Excludes insulation, charge/discharge equipment and controls — this is the TANK only, so it understates a delivered TES system."
                }
            },
            "s_ref": 500000,
            "c_ref": 192075,
            "c_ref_cost_year": 1998,
            "needs_reanchoring": true,
            "n_eqp": 0.7381,
            "n_inst": 0.6288,
            "icm_ref": 1.505,
            "valid_min": 50000,
            "valid_max": 10000000,
            "max_single_unit": null,
            "evidence": "estimated",
            "fit": {
                "method": "OLS on log-transformed cost and capacity",
                "r2_eqp": 0.986,
                "r2_inst": 0.966,
                "n_points": 4,
                "source_id": "netl-1169"
            },
            "sources": [
                "netl-1169"
            ],
            "notes": "PARTIAL SCOPE. Tank shell only. The UI must state that charge/discharge plant, insulation and controls are excluded. 500,000 gal ≈ 61 MWh_th at the defaults."
        }
    ]
}