    "set_id": "generation-storage",
    "set_name": "Generation & storage",
    "version": "2026.1",
    "status": "seed",
    "published": "2026-11-01",
    "base_currency": "USD",
    "base_region": "NA",
    "accuracy": {
        "class": "AACE Class 5",
        "definition": "0–2% project definition, concept screening",
        "low_pct": [
            -20,
            -50
        ],
        "high_pct": [
            30,
            100
        ],
        "source": "AACE International Recommended Practice 18R-97"
    },
    "location_factors": {
        "_comment": "Location factors are ESTIMATED and INPUT-PRICE ONLY - they exclude delivery-environment cost. Published with a range and a coverage grade in data/location-factors-2026.1.json; the range must be shown wherever the point value is. Base region NA = 1.000 by definition (US Gulf Coast). See 16-location-factors.md.",
        "NA": 1,
        "EU": 0.957,
        "APAC": 0.931,
        "SAM": 0.931,
        "MEA": 0.887
    },
    "sources": [
        {
            "id": "eia-capcost",
            "title": "Capital Cost and Performance Characteristics for Utility Scale Electric Power Generating Technologies",
            "publisher": "US EIA",
            "url": "https://www.eia.gov/analysis/studies/powerplants/capitalcost/pdf/capital_cost_AEO2025.pdf",
            "licence": "US federal — public domain",
            "cost_year": 2023
        },
        {
            "id": "nrel-storage-2025",
            "title": "Cost Projections for Utility-Scale Battery Storage: 2025 Update",
            "publisher": "NREL",
            "url": "https://docs.nrel.gov/docs/fy25osti/93281.pdf",
            "licence": "US federal — public domain",
            "cost_year": 2024
        }
    ],
    "equipment": [
        {
            "id": "utilityPV",
            "name": "Utility-scale solar PV, single-axis tracking",
            "status": "seeded_provisional",
            "model": "power_law",
            "c_ref_basis": "installed",
            "rating": {
                "unit": "MWac",
                "label": "MW AC",
                "basis": "AC rating at the point of interconnection",
                "note": "DC and AC ratings differ by roughly 25–30%. The calculator MUST require the user to state which they are entering.",
                "dc_ac_ratio_default": 1.3
            },
            "s_ref": 150,
            "c_ref": 225300000,
            "c_ref_cost_year": 2023,
            "needs_reanchoring": false,
            "n_eqp": null,
            "n_inst": 0.9,
            "icm_ref": null,
            "valid_min": 20,
            "valid_max": 500,
            "max_single_unit": null,
            "evidence": "assumed",
            "fit": {
                "method": "none — single published point",
                "n_points": 1,
                "source_id": "eia-capcost"
            },
            "needs_regression": true,
            "sources": [
                "eia-capcost"
            ],
            "notes": "C_ref is EIA's overnight installed cost at 150 MWac ($1,502/kW, 2023$) — installed only, no equipment/installed split published, so ICM is null and the equipment line cannot be shown. n_inst = 0.90 is ASSUMED on the grounds that PV is highly modular; it is NOT regressed. Replace with a fit against LBNL Utility-Scale Solar installed cost by project size band — that is the single highest-value regression outstanding."
        },
        {
            "id": "bess",
            "name": "Battery energy storage, lithium-ion",
            "status": "seeded",
            "model": "linear_decomposition",
            "c_ref_basis": "installed",
            "rating": {
                "unit": "MW+MWh",
                "label": "MW power and hours duration",
                "basis": "AC-coupled, installed",
                "note": "Storage cost depends on power AND energy independently. A single per-MW figure is meaningless without duration — the calculator MUST require both."
            },
            "s_ref": null,
            "c_ref": null,
            "c_ref_cost_year": 2024,
            "n_eqp": null,
            "n_inst": null,
            "icm_ref": null,
            "decomposition": {
                "expression": "total_usd_per_kw = energy_usd_per_kwh * duration_hours + power_usd_per_kw",
                "energy_usd_per_kwh": 241,
                "power_usd_per_kw": 372,
                "cost_year": 2024,
                "check": {
                    "duration_hours": 4,
                    "expected_usd_per_kw": 1336,
                    "expected_usd_per_kwh": 334
                }
            },
            "valid_min": 1,
            "valid_max": 500,
            "valid_duration_min": 1,
            "valid_duration_max": 10,
            "max_single_unit": null,
            "evidence": "measured",
            "fit": null,
            "sources": [
                "nrel-storage-2025"
            ],
            "notes": "Decomposition and 2024 values from NREL. NREL states explicitly that duration must be cited whenever a capital cost is given in $/kWh or $/kW. No power-law scaling is applied — BESS is built from modules and scales close to linearly."
        }
    ]
}